TYPE OF TESTS REQUIRED

  • Groove weld, Clause 6.17 (non-tubular) and Clause 10.16 (tubular)
  • Substitution of RT for guided bend tests: Clause 6.23.3 (non-tubular) and Clause 10.21.2 (tubular).

TACK WELDERS

  • For non-tubular, Clause 6.17.2 and Clause 6.24.
  • For tubular, Clause 10.17.

TEST SPECIMENS

  • Non-tubular
    o Welder, Clause 6.21.1, length of test coupon L = 180 mm (recommended 200 mm).
    o Welding operator, Clause 6.21.2, length of test coupon L = 380 mm (recommended 400 mm).
  • Tubular
    o Welder and Welding operator, Clause 10.17, also Clause 10.21.2, length of test coupon L = 150 mm.

ESSENTIAL VARIABLES

  • Clause 6.20 and Table 6.12.

WQT FORMS

PERIOD OF EFFECTIVENESS

  • Within six months, Clause 6.2.3
  • Retest, Clause 6.25.1

FQA

  • Qualification responsibility, see Clause 6.2.2.2.
  • Change F-Number are not allowed, see Table 6.12 line 2 and Table 6.13.
  • Test specimens are recommended DN 200 12.7 mm.
  • Third party should invite to endorse the documents, such ABS, DNV, LR, BV or other international society classification.

 


Download WQT form and request for services.


 

Leave a comment


This site uses Akismet to reduce spam. Learn how your comment data is processed.


FIND YOUR TOOL ON AMAZON

wic_amazon
WIC-2560x512 Community

Services

Contact Us

Following Us

Disclaimer: Weldinginspections.net is based on information from multiple sources and our experience with welding and inspection scopes. It is not a replacement for manufacturers directions and is only to provide reminders for inspector.